Display Data Logger Manufacturer,Supplier and Exporter in India

Display Data Logger

Product Code : TVT-MTE-10714
Tvet Equipments is a leading Display Data Logger Manufacturer,and suppliers in India, Display Data Logger Uruguay (Montevideo), Display Data Logger Uzbekistan (Tashkent), Display Data Logger Venezuela (Caracas), Display Data Logger Vietnam (Hanoi), Display Data Logger Yemen (Sana'a), Display Data Logger Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

Temperature Measurement
Data Logger with 4.3 inch color display, 10 isolated analog channels, 4 digital channels, 4 alarm outputs, 4GB internal memory, SDHC card slot (max 32GB), USB PC interface. Includes APS software, start-up manual, AC power supply.

Features :
- Wireless LAN capability | remote monitoring & datalogging
- Extended memory capacity using SD memory card
- Max sampling interval up to 10ms
- Smartphone access
- Flexible input system for wide array of applications
- Ability to access additional  sensors & adapters

Technical Specifications : 

Input Method

 All channels isolated balanced input, scans channels for sampling

Type of Input Terminal   

 Screw terminal (M3 screw)  

Measurement Range

 Voltage : 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50, 100 V & 1-5V F.S. (Full Scale)
 Thermocouple Type : K, J, E, T, R, S, B, N, and W (WRe5-26)
 Humidity : 0 to 100 % RH - using the humidity sensor (option B-530)

Filter

 Off, 2, 5, 10, 20, 40 (moving average in selected number)

Measurement Accuracy

 Voltage : ± 0.1% of F.S. (Full Scale)
 Temperature (Thermocouple)

A/D Converter

 Sigma-Delta type, 16 bits (effective resolution: 1/40000 of the measuring full range)

Maximum Input Voltage

 1) Between (+) / (-) terminal :

 - 20 mV to 1 V range: 60 Vp-p,
 - 2 V to 100 V range: 110 Vp-p

 2) Channels ((-) / (-)) : 60 Vp-p
 3) Channel / GND : 60 Vp-p

Max. Voltage (withstand)

 Between channels : 350 Vp-p (1 minute)
 Channel / GND : 350 Vp-p (1 minute)

 

   

Office Address

Works: Tugalpur, S Sector KP-1, Behind Kailash Hospital,
Greater Noida City - 201310. Uttar Pradesh

[email protected]

+91-98173-19615